<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Transducers - Tera Coldchain</title>
	<atom:link href="https://tera-coldchain.com/en/category/transducers/feed/" rel="self" type="application/rss+xml" />
	<link>https://tera-coldchain.com</link>
	<description></description>
	<lastBuildDate>Thu, 03 Oct 2024 19:24:47 +0000</lastBuildDate>
	<language>en-GB</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.3.1</generator>

<image>
	<url>https://tera-coldchain.com/wp-content/uploads/2022/10/favicon.png</url>
	<title>Transducers - Tera Coldchain</title>
	<link>https://tera-coldchain.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Y-Case Wireless Humidity &#038; Temperature Transducers w/ ZigBee 868MHz</title>
		<link>https://tera-coldchain.com/en/y-case-wireless-humidity-temperature-transducers-w-zigbee-868mhz/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=y-case-wireless-humidity-temperature-transducers-w-zigbee-868mhz</link>
		
		<dc:creator><![CDATA[admin_tc]]></dc:creator>
		<pubDate>Mon, 26 Sep 2022 22:36:47 +0000</pubDate>
				<category><![CDATA[Transducers]]></category>
		<guid isPermaLink="false">http://109.87.155.3:9999/?p=784</guid>

					<description><![CDATA[<p>Y-Case Wireless Humidity &#38; Temperature Transducers ZigBee 868 use ZigBee interface with frequency 868 MHz for data transfer. The transducer works by the following sequence: [&#8230;]</p>
<p>The post <a href="https://tera-coldchain.com/en/y-case-wireless-humidity-temperature-transducers-w-zigbee-868mhz/">Y-Case Wireless Humidity & Temperature Transducers w/ ZigBee 868MHz</a> first appeared on <a href="https://tera-coldchain.com">Tera Coldchain</a>.</p>]]></description>
										<content:encoded><![CDATA[<div class="product-images-container"><img decoding="async" class="alignnone" src="/wp-content/uploads/2022/09/zigbee_2-01_main_page.jpg" alt="Wireless Humidity &amp; Temperature Transducers Y 2-01" width="93" height="346" /><br />
<img decoding="async" class="alignnone" src="/wp-content/uploads/2022/09/zigbee_2-02_main_page.jpg" alt="Wireless Humidity &amp; Temperature Transducers Y 2-02" width="93" height="346" /><br />
<img decoding="async" class="alignnone" src="/wp-content/uploads/2022/09/zigbee_2-15_main_page-2.jpg" alt="Wireless Humidity &amp; Temperature Transducers Y 2-15" width="138" height="346" /><br />
<img decoding="async" loading="lazy" class="alignnone" src="/wp-content/uploads/2022/09/zigbee_2-18_main_page-2.jpg" alt="Wireless Humidity &amp; Temperature Transducers Y 2-18" width="110" height="346" /><br />
<img decoding="async" loading="lazy" class="alignnone" src="/wp-content/uploads/2022/09/zigbee_2-19_main_page-2.jpg" alt="Wireless Humidity &amp; Temperature Transducers Y 2-19" width="70" height="346" /><br />
<img decoding="async" loading="lazy" class="alignnone" src="/wp-content/uploads/2022/09/zigbee_2-21_main_page-2.jpg" alt="Wireless Humidity &amp; Temperature Transducers Y 2-21" width="70" height="346" /></div>
<div><strong>Y-Case Wireless Humidity &amp; Temperature Transducers ZigBee 868</strong> use ZigBee interface with frequency 868 MHz for data transfer. The transducer works by the following sequence: turning on, measuring, data transferring, turning off. In other words, the frequent measuring make quicker the batteries out. Transducer operation require an <strong>Data Logger CS10600</strong> and a wireless <strong>Net Coordinator Y6.05-K-868</strong>.The transducer uses high contrast OLED display for indications. It displays measurements for each transducer&#8217;s measuring channel. In addition, it&#8217;s able to display radio signal level, battery charge, serial number and network settings. The transducer may be supplied with magnetic holder and a mounting board, that may mounted with screws.</p>
<p>The transducer may have several sensors depending on a model. A humidity &amp; temperature sensor SHT31 is set up inside of transducer&#8217;s case. In addition, depending on a model, the transducer can be connected by one or two external temperature analogue Pt1000 probes with a cable and M5/M8 connectors.</p>
</div>
<p><a href="/wp-content/uploads/2024/01/zb_humtemp_en.pdf" target="_blank" rel="noopener">Specifications</a></p><p>The post <a href="https://tera-coldchain.com/en/y-case-wireless-humidity-temperature-transducers-w-zigbee-868mhz/">Y-Case Wireless Humidity & Temperature Transducers w/ ZigBee 868MHz</a> first appeared on <a href="https://tera-coldchain.com">Tera Coldchain</a>.</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Y-Case Wired Humidity &#038; Temperature Transducers w/ RS485 Signal and М12 Connector</title>
		<link>https://tera-coldchain.com/en/y-case-wired-humidity-temperature-transducers-w-rs485-signal-and-m12-connector/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=y-case-wired-humidity-temperature-transducers-w-rs485-signal-and-m12-connector</link>
		
		<dc:creator><![CDATA[admin_tc]]></dc:creator>
		<pubDate>Mon, 26 Sep 2022 22:24:30 +0000</pubDate>
				<category><![CDATA[Transducers]]></category>
		<guid isPermaLink="false">http://109.87.155.3:9999/?p=722</guid>

					<description><![CDATA[<p>Y-Case Humidity and Temperature Tranducers RS485 use RS485 interface for data transfer. This wired interface allows to connect consistently up to 30 probes using a [&#8230;]</p>
<p>The post <a href="https://tera-coldchain.com/en/y-case-wired-humidity-temperature-transducers-w-rs485-signal-and-m12-connector/">Y-Case Wired Humidity & Temperature Transducers w/ RS485 Signal and М12 Connector</a> first appeared on <a href="https://tera-coldchain.com">Tera Coldchain</a>.</p>]]></description>
										<content:encoded><![CDATA[<div class="product-images-container"><img decoding="async" loading="lazy" class="alignnone" src="/wp-content/uploads/2022/09/rs485_2-01_main_page.jpg" alt="Y-Case Humidity and Temperature Tranducers RS485 Model 2-01" width="92" height="346" /><br />
<img decoding="async" loading="lazy" class="alignnone" src="/wp-content/uploads/2022/09/rs485_2-02_main_page.jpg" alt="Y-Case Humidity and Temperature Tranducers RS485 Model 2-02" width="95" height="346" /><br />
<img decoding="async" loading="lazy" class="alignnone" src="/wp-content/uploads/2022/09/rs485_2-16_main_page_3.jpg" alt="Y-Case Humidity and Temperature Tranducers RS485 Model 2-16" width="186" height="346" /><br />
<img decoding="async" loading="lazy" class="alignnone" src="/wp-content/uploads/2022/09/rs485_2-17_main_page-2-1.jpg" alt="Y-Case Humidity and Temperature Tranducers RS485 Model 2-17" width="93" height="346" /></div>
<div><strong>Y-Case Humidity and Temperature Tranducers RS485</strong> use RS485 interface for data transfer. This wired interface allows to connect consistently up to 30 probes using a single cable line. The transducer is connected to RS485 by 5 wired scheme. For networking it uses FTP 5e cables. RS485 connection is carried out by sealed thread M12 connector with internal terminal block (no soldering). It allows to dismount the transducer easily, when it requires verification or calibration. The transducer is supplied with junction box CP-06 and its power supply. Transducer&#8217;s power supply is set up inside of CP-06, as well as the terminal block for easy arrangement of RS485 input and output cables.The transducer may have several sensors depending on a model. Humidity and temperature built-in SHT31 sensor is placed inside of transducer&#8217;s case (2-16 and 2-17 models). In addition, it&#8217;s available to connect external temperature analogue Pt1000 temperature probe with a sealed thread M8 connector for 2-17 model, and two external temperature probes via non-sealed thread M5 connectors for 2-16 model. 2-16 and 2-17 models is supplied with magnets and mounting board with screws to mount it easily on the vertical surface.</p>
</div>
<p><a href="/wp-content/uploads/2024/01/rs_humtemp_en.pdf" target="_blank" rel="noopener">Specifications</a><br />
<a href="/wp-content/uploads/2022/11/ce-tsp-dvt.pdf" target="_blank" rel="noopener">Certificate</a></p><p>The post <a href="https://tera-coldchain.com/en/y-case-wired-humidity-temperature-transducers-w-rs485-signal-and-m12-connector/">Y-Case Wired Humidity & Temperature Transducers w/ RS485 Signal and М12 Connector</a> first appeared on <a href="https://tera-coldchain.com">Tera Coldchain</a>.</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Y-Case Wireless Temperature Transducers w/ ZigBee 868MHz</title>
		<link>https://tera-coldchain.com/en/y-case-wireless-temperature-transducers-w-zigbee-868mhz/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=y-case-wireless-temperature-transducers-w-zigbee-868mhz</link>
		
		<dc:creator><![CDATA[admin_tc]]></dc:creator>
		<pubDate>Mon, 26 Sep 2022 21:15:24 +0000</pubDate>
				<category><![CDATA[Transducers]]></category>
		<guid isPermaLink="false">http://109.87.155.3:9999/?p=652</guid>

					<description><![CDATA[<p>Y-Case Wireless Temperature Transducers ZigBee 868 use ZigBee interface with frequency 868 MHz for data transfer. The transducer works by the following sequence: turning on, [&#8230;]</p>
<p>The post <a href="https://tera-coldchain.com/en/y-case-wireless-temperature-transducers-w-zigbee-868mhz/">Y-Case Wireless Temperature Transducers w/ ZigBee 868MHz</a> first appeared on <a href="https://tera-coldchain.com">Tera Coldchain</a>.</p>]]></description>
										<content:encoded><![CDATA[<div class="product-images-container"><img decoding="async" loading="lazy" class="alignnone" src="/wp-content/uploads/2022/09/wireless_1-3_main_page.jpg" alt="Y-Case Wireless Temperature Transducer w/ ZigBee 868MHz Model 1-3" width="76" height="280" /><br />
<img decoding="async" loading="lazy" class="alignnone" src="/wp-content/uploads/2022/09/zigbee_1-3n_main_page2.jpg" alt="Y-Case Wireless Temperature Transducer w/ ZigBee 868MHz Model 1-3n" width="93" height="280" /><br />
<img decoding="async" loading="lazy" class="alignnone" src="/wp-content/uploads/2022/09/wireless_1-4_main_page.jpg" alt="Y-Case Wireless Temperature Transducer w/ ZigBee 868MHz Model 1-4" width="77" height="280" /><br />
<img decoding="async" loading="lazy" class="alignnone" src="/wp-content/uploads/2022/09/zigbee_2-15_main_page.jpg" alt="Y-Case Wireless Temperature Transducer w/ ZigBee 868MHz Model 2-15" width="138" height="280" /><br />
<img decoding="async" loading="lazy" class="alignnone" src="/wp-content/uploads/2022/09/zigbee_2-18_main_page.jpg" alt="Y-Case Wireless Temperature Transducer w/ ZigBee 868MHz Model 2-18" width="110" height="280" /><br />
<img decoding="async" loading="lazy" class="alignnone" src="/wp-content/uploads/2022/09/zigbee_2-19_main_page.jpg" alt="Y-Case Wireless Temperature Transducer w/ ZigBee 868MHz Model 2-19" width="70" height="280" /><br />
<img decoding="async" loading="lazy" class="alignnone" src="/wp-content/uploads/2022/09/zigbee_2-21_main_page.jpg" alt="Y-Case Wireless Temperature Transducer w/ ZigBee 868MHz Model 2-21" width="70" height="280" /></div>
<p><strong>Y-Case Wireless Temperature Transducers ZigBee 868</strong> use ZigBee interface with frequency 868 MHz for data transfer. The transducer works by the following sequence: turning on, measuring, data transferring, turning off. In other words, the frequent measuring make quicker the batteries out. Transducer operation require an <strong>Data Logger CS10600</strong> and a wireless <strong>Net Coordinator Y6.05-K-868</strong>.</p>
<p>The transducer uses high contrast OLED display for indications. It displays measurements for each transducer&#8217;s measuring channel. In addition, it&#8217;s able to display radio signal level, battery charge, serial number and network settings. The transducer may be supplied with magnetic holder and a mounting board, that may mounted with screws.</p>
<p>The transducer may have one, two or three temperature sensors depending on a model. A temperature sensor TMP116 is set up inside of transducer&#8217;s case. In addition, depending on a model, the transducer can be connected by one or two external temperature analogue Pt1000 probes, either one XA probe with a cable and M5/M8/M12 connectors.</p>
<p><a href="/wp-content/uploads/2024/01/zb_temp_en.pdf" target="_blank" rel="noopener">Specifications</a></p><p>The post <a href="https://tera-coldchain.com/en/y-case-wireless-temperature-transducers-w-zigbee-868mhz/">Y-Case Wireless Temperature Transducers w/ ZigBee 868MHz</a> first appeared on <a href="https://tera-coldchain.com">Tera Coldchain</a>.</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Y-Case Wired Temperature Transducers w/ RS485 Signal and М12 Connector</title>
		<link>https://tera-coldchain.com/en/y-case-wired-temperature-transducers-w-rs485-signal-and-m12-connector/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=y-case-wired-temperature-transducers-w-rs485-signal-and-m12-connector</link>
		
		<dc:creator><![CDATA[admin_tc]]></dc:creator>
		<pubDate>Mon, 26 Sep 2022 01:08:41 +0000</pubDate>
				<category><![CDATA[Transducers]]></category>
		<guid isPermaLink="false">http://109.87.155.3:9999/?p=590</guid>

					<description><![CDATA[<p>Y-Case Temperature Tranducers RS485 use RS485 interface for data transfer. This wired interface allows to connect consistently up to 30 probes using single cable line. [&#8230;]</p>
<p>The post <a href="https://tera-coldchain.com/en/y-case-wired-temperature-transducers-w-rs485-signal-and-m12-connector/">Y-Case Wired Temperature Transducers w/ RS485 Signal and М12 Connector</a> first appeared on <a href="https://tera-coldchain.com">Tera Coldchain</a>.</p>]]></description>
										<content:encoded><![CDATA[<div class="product-images-container"><img decoding="async" loading="lazy" class="alignnone" src="/wp-content/uploads/2022/09/rs485_1-3_main_page.jpg" alt="Y-Case Temperature Tranducer RS485 1-3" width="93" height="346" /><br />
<img decoding="async" loading="lazy" class="alignnone" src="/wp-content/uploads/2022/09/rs485_1-3n_main_page-2.jpg" alt="Y-Case Temperature Tranducer RS485 1-3n" width="93" height="346" /><br />
<img decoding="async" loading="lazy" class="alignnone" src="/wp-content/uploads/2022/09/rs485_1-4_main_page.jpg" alt="Y-Case Temperature Tranducer RS485 1-4" width="93" height="346" /><br />
<img decoding="async" loading="lazy" class="alignnone" src="/wp-content/uploads/2022/09/rs485_2-16_main_page_2.jpg" alt="Y-Case Temperature Tranducer RS485 2-16" width="186" height="346" /><br />
<img decoding="async" loading="lazy" class="alignnone" src="/wp-content/uploads/2022/09/rs485_2-17_main_page-2.jpg" alt="Y-Case Temperature Tranducer RS485 2-17" width="93" height="346" /></div>
<div>
<p><strong>Y-Case Temperature Tranducers RS485</strong> use RS485 interface for data transfer. This wired interface allows to connect consistently up to 30 probes using single cable line. The probe connects to RS485 line by 5 wired scheme. For networking it&#8217;s using FTP 5e cables. RS485 connection is implemented by sealed thread M12 connector with internal terminal block (no soldering). It allows to dismount the probe easily, when it needs verification or calibration.</p>
<p>The probe provides with junction box CP-06 and its power supply. Probe&#8217;s power supply is mounted inside of CP-06, as well as the terminal block for easy arrangement of RS485 input and output cables.</p>
<p>The high contrast screen is using for data display, that informs current measuring value by every channel, serial number and RS485 settings. It&#8217;s available to order 2-17 model with several sensors: besides of mounted temperature sensor, a customer may order one external probe Pt1000 or XA, that connects to the probe by sealed thread M8 connector. 2-16 model allows to have two external probes Pt1000, that connects by non-sealed thread M5 connector. 2-16 and 2-17 models provide with magnet and mounting board with screws to mount it easily on the vertical surface.</p>
</div>
<p><a href="/wp-content/uploads/2024/01/rs_temp_en.pdf" target="_blank" rel="noopener">Specifications</a><br />
<a href="/wp-content/uploads/2022/11/ce-tsp-dvt.pdf" target="_blank" rel="noopener">CE certificate</a></p>
<p>See also:</p>
<ul>
<li><a href="https://tera-coldchain.com/en/y-case-wireless-temperature-transducers-w-zigbee-868mhz/">Y-Case Wireless Temperature Transducers w/ ZigBee 868MHz</a>;</li>
<li><a href="https://tera-coldchain.com/en/y-case-wired-humidity-temperature-transducers-w-rs485-signal-and-m12-connector/">Y-Case Wired Humidity &amp; Temperature Transducers w/ RS485 Signal and М12 Connector</a>;</li>
<li><a href="https://tera-coldchain.com/en/y-case-wireless-humidity-temperature-transducers-w-zigbee-868mhz/">Y-Case Wireless Humidity &amp; Temperature Transducers w/ ZigBee 868MHz</a>.</li>
</ul><p>The post <a href="https://tera-coldchain.com/en/y-case-wired-temperature-transducers-w-rs485-signal-and-m12-connector/">Y-Case Wired Temperature Transducers w/ RS485 Signal and М12 Connector</a> first appeared on <a href="https://tera-coldchain.com">Tera Coldchain</a>.</p>]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>