CS10600 Data Logger

CS10600 Data Logger

CS10600 Data Logger is using for data collecting produced by wired and wireless humidity and temperature transducers. The transducers are available to tranfer data to the Data Logger using RS485 interface, and via Y6.05-K-868 Net Coordinator by 868 MGz frequency radiosignal. The single Data Logger may operate up to 30 transducers. The Data Logger saves all data in energy-independent flash memory, and may duplicate it on cloud or corporate servers.

The Data Logger operates on Linux OS. Archive data stores on SQL Lite database. A web server with WEB HMI SCADA LOCAL WEB is installed directly on the Data Logger. It uses HMI user interface, developed on the standard markup web languages. The Local Web displays received information by using charts and tables, creating reports, info export as a PDF-file, transducer settings, setting and mailing alarm signalization via messengers and SMS, leading and saving archive data, technology journals and signing the users in.

The Data Logger uses Ethernet connection or 4G LTE for networking. When the user wants to get information, it’s needed just to follow the link in the web browser by signing in on the web server. The LOCAL WEB easily runs in the Chrome browser on the varies of devices such as a smartphone, a PC, etc. If networking via Ethernet is disabled, the user may receive an access using built-in 4G LTE modem by SIM card with mobile internet.

Scheme of operation of the data logger

Besides of setting up the alarm signalization by assignment operating humidity and temperature range, the Data Logger is available to set up the alarm signalization in case of absence of transducer connection, absence of Internet connection via Ethernet and 4G LTE, switch from the uninterruptible power supply to the battery.

It’s available to connect via RS485 interface (T-bus protocol) the technological controllers and meters powered by PJSC TERA. In this case, a user may view monitoring and archived data, as well as to control technical processes by WEB HMI interface through LOCAL WEB software.

The Data Logger has 7″ capacitive touch screen to ease interface of monitoring data display by its location.

Technical Specifications

System Interface Ethernet, 4G LTE, 2 x RS485
System Interface for Wired Transducers RS485, T-bus Protocol
System Interface for Wireless Transducers RS485, T-bus Protocol, via Y6.05-K-868 Net Coordinator
using 868 MGz Frequency Radiosignal
Memory Capacity 16 GB (eMMC)
Database SQL Lite
Operating System Linux (Raspberry Pi OS)
Power Supply 24 V DC 250 mA
Housing Material Aluminium
Operating Temperature, °C -20 … 50
Display 7.0 inch IPS LCD, 1024*600 Pixel Resolution
High Brightness: 500nit
Touch Screen Capacitive Touch (Five-Point)

The shield with the uninterruptible power supply

Photo of the shield with the uninterruptible power supply, view from outside and inside.

The shield with the uninterruptible power supply is recommended to use for powering CS10600 data logger in systems, where the backup power is critically necessary, and serving as the surge suppressor.

The shield supplies with power CS10600 data logger. It transduces mains power 230 VDC to 24 VDC. The shield contains two replaceable AGM storage batteries (gel-based lead-acid) with capacity 9 Ah for each one to power the data logger and a net of coordinators uninterruptibly during 20 hours in a case when there is no mains power (depends on a number of coordinators on RS485 line).

Signals of presence/absence 230 VDC and a signal of discharge of the batteries are provided in the power source of CS10600 data logger.

 

Technical Specifications

Input Voltage 90…240 VDC
Output stabilized Voltage 24 VDC 1000 мА
Battery Capacity 2 х 9 Ah / 12 V
Battery Type AGM (2 pcs.)
Contact for Disabled / Enabled Mains Supply There is
Housing Material Metal
Dimensions, mm 425 х 425 х 208 (L х W х D)
Operating Temperature, °C 0…45

 